top of page

Underwater Solutions for a Wide Variety of
Deep Sea and Shallow Water Applications

The new, compact, and easy-to-operate AquapHOx underwater sensor platforms are flexible solutions for many applications. Besides stand-alone loggers with internal data storage for long term deployment, our transmitters offer fast sampling and easy integration into existing set-ups utilizing the integrated analog outputs.

​

The loggers and transmitters are available with a titanium housing for deep-sea applications to depths of 4000m. These devices are highly flexible when choosing your analyte and sensor format as optical oxygen, pH, and temperature sensors can be connected. 

​

For applications in shallow water, loggers and transmitters with a POM housing are available and can be deployed to depths of 200m. These devices are dedicated to one analyte but with the same flexibility concerning sensor format (i.e., caps or fiber-based sensor).

​

All AquapHOx models are ideally suited for measurements in a variety of marine monitoring applications, including:

Ocean Habitats

Open Ocean

Deep Sea

Aquaculture

Coastal Habitats (i.e., coral reefs)

Others

AquapHOx Loggers
  • Includes battery and data storage

  • Standalone logging

  • Monitoring/long-term deployment

  • Sample Interval: 1s

AquapHOx Transmitters
  • DOES NOT include battery or data storage

  • Must be integrated

  • Real-time data transmission to the surface

  • Fast profiling with higher sample interval (0.025s)

VS.

Water Column & Sediment Profiling

Oxygen Minimum Zones Monitoring

In-Situ Incubations, etc.

PyroScience Ocean Monitoring Article.jpg

Click to read a recently published

article in ECO Magazine!

Flexible-Analyte Deep Sea Loggers and Transmitters
Operation to depths of 4000m with a broad range of O2, pH, and temperature
Compatible Sensors for AquapHOx Loggers and Transmitters
All Sensors include Underwater SUB-connector
Shallow Water Oxygen Loggers and Transmitters
Operation to depths of 200m
Shallow Water pH Loggers and Transmitters
Operation to depths of 200m
APHOX-LX.jpg

APHOX-LX

  • APHOX-LX​​

    • Stand-alone logging for >1 year

    • Integrated rechargeable battery

    • Integrated fast Pt100 temperature sensor

  • APHOX-TX

    • Measurements with 40 Hz possible​

    • For profiling and eddy covariance set-ups

    • Analog outputs / USB / RS485/ Modbus

OXR430-UHS-SUB.jpg

OXR430-UHS-SUB

PHCAP-PK8T-SUB.jpg

PHCAP-PK8T-SUB

TPROBSC-SUB.jpg

TPROBSC-SUB

Oxygen Sensors and Caps (No oxygen consumption, Negligible drift)​

  • OXR430-UHS-SUB: Retractable fiber 430µm in diameter, ultra-high speed response time (t90 < 0.3s)

  • OXR430-HS-SUB: Retractable fiber 430µm in diameter, high speed response time (t90 < 0.8s)

  • OXR50-OI-SUB: Retractable fiber 230µm in diameter, 50-70µm sharp sensor tip, optically isolated (OI)

  • OXROBSC-SUB: Robust screw cap probe with 2 oxygen screw cap sensors, optically isolated (OI)

  • OXROB10-CL4-SUB: Stainless steel 10cm long, 3mm in diameter, 4m cable length (CL4), OI

  • OXROB3-SUB: Stainless steel 3cm long, 3mm in diameter, optically isolated (OI)

  • OXROB3-CL4-SUB: Stainless steel 3cm long, 3mm in diameter, 4m cable length (CL4), OI

  • OXCAP-SUB: Optical oxygen sensor screw cap, fast sensor with low drift

  • UTROXCAP-SUB: Optical ultra-trace oxygen sensor screw cap, fast sensor with low drift

  • OXCAPG-UHS-SUB: Optical oxygen sensor screw cap, ultra high speed response time (t90 < 0.5s)

  • OXCAPG-HS-SUB: Optical oxygen sensor screw cap, high speed response time (t90 < 1s)

pH Sensors and Caps (Minimal cross-sensitivity to high ionic strength)

  • PHCAP-PK8T-SUB: Robust optical pH sensor cap, 7.0-9.0 range pH total scale

  • PHCAP-PK8-SUB: Robust optical pH sensor cap, measurement range pH 7.0-9.0

  • PHCAP-PK7-SUB: Robust optical pH sensor cap, measurement range pH 6.0-8.0

  • PHROBSC-PK8T-SUB: Robust pH Probe, 6.0-8.0 range pH total scale, exchangeable Screw Caps

  • PHROBSC-PK8-SUB: Measurement range pH 6.0-8.0, exchangeable Screw Caps

  • PHROBSC-PK7-SUB: Measurement range pH 7.0-9.0, exchangeable Screw Caps

Temperature Sensors (Measurement range of 0°C - 50°C, Fast response time (<<1s))

  • TPROBSC-SUB: Only for shallow-water applications

  • TPR430-SUB: Retractable fiber 430µm in diameter

  • TPB430-SUB: Optical fiber 430µm in diameter

  • TPF1100-SUB: Fixed needle temperature probe

APHOX-L-O2.jpg

APHOX-L-O2

  • APHOX-L-O2

    • Broad range of optical oxygen sensors

    • Stand-alone logging for >1 year

    • Integrated rechargeable battery

    • Integrated fast Pt100 temperature sensor 

  • APHOX-T-O2

    • Measurements with 40Hz possible​

    • For profiling and eddy covariance set-ups

    • Broad range of optical oxygen sensors

    • Analog outputs / USB / RS485 / Modbus

  • APHOX-L-PH

    • Broad range of optical pH sensors​

    • Stand-alone logging for >1 year

    • Integrated rechargeable battery

    • Integrated fast Pt100 temperature sensor 

  • APHOX-T-PH​

    • Broad range of optical pH sensors

    • Analog outputs / USB / RS485 / Modbus

APHOX-L-PH.jpg

APHOX-L-PH

Top of Page
PICO Series OEM Meters
1-channel underwater OEM device
PICO-O2-SUB.jpg

PICO-O2-SUB

  • PICO-O2-SUB​​

    • Broad range of different compatible sensors

    • Compact dimensions 59 x Ø17 mm

    • Very low power consumption

    • UART interface

  • PICO-PH-SUB

    • Compact dimensions 59 x Ø17 mm

    • Very low power consumption

    • UART interface

Accessories
PHCAL2.jpg

PHCAL2

  • PHCAL2: Required for acid calibration of optical pH sensors, 10 capsules

  • PHCAL11: Required for basic calibration of optical pH sensors, 10 capsules

  • OXCAL: Recommended 0% O2 calibration of optical oxygen sensors, 10 capsules

  • APHOX-T-PIG: Transmitter inline cable (pigtail) for custom cable assemblies, ca. 60cm length

  • APHOX-T-VECTOR: For Nortek® Vector acoustic doppler velocimeter connection

  • PICO-USB: USB interface cable for evaluation of PICO-O2, PICO-PH, and PICO-T, incl. software

  • PICO-EXT: Modbus analog out module for the ultra-compact optical PICO OEM modules

  • TSUB21-NC: Flexible Teflon-coated temperature probe, no connector for soldering, Tip and cable submersible in water

APHOX-FTC Contactless Underwater Flow-through-cell

  • For APHOX®-T and APHOX®-L devices

  • Fully submergable

  • Usable in the Field and In-Lab

  • Compatible with all CAP and SUB-connector sensor

APHOX-FTC .jpg
Compatible Sensors for PICO Series OEM Meters
All Sensors include Underwater SUB-connector
OXCAP-SUB.jpg

OXCAP-SUB

PHCAP-PK8T-SUB.jpg

PHCAP-PK8T-SUB

​Oxygen Sensors and Caps (no oxygen consumption, negligible drift)​​

  • OXCAP-SUB: Optical oxygen sensor screw cap, fast sensor with low drift

  • UTROXCAP-SUB: Optical ultra-trace oxygen sensor screw cap, fast sensor with low drift

  • OXCAPG-UHS-SUB: Optical oxygen sensor screw cap, ultra high-speed response time (t90 < 0.5s),

  • OXCAPG-HS-SUB: Optical oxygen sensor screw cap, high-speed response time (t90 < 1s)

  • OXSP5-SUB: Sensor spots (8 pcs.) 5mm in diameter, no oxygen consumption

  • OXR430-UHS-SUB: Retractable fiber 430µm in diameter, ultra-high speed response time (t90 < 0.3s)

  • OXR430-HS-SUB: Retractable fiber 430µm in diameter, high-speed response time (t90 < 0.8s)

  • OXR430-OI-SUB: Retractable fiber 430µm in diameter, optically isolated (OI)

  • OXR430-SUB: Retractable fiber 430µm in diameter

  • OXR50-UHS-SUB: Retractable fiber, 50-70µm sensor tip, ultra-high speed response time (t90 < 0.3s)

  • OXR50-HS-SUB: Retractable fiber 230µm, 50-70µm sensor tip, high speed response time (t90 < 0.8s)

  • OXR50-OI-SUB: Retractable fiber 230µm in diameter, 50-70µm sharp sensor tip, optically isolated (OI)

  • OXROBSC-SUB: Robust screw cap probe with 2 oxygen screw cap sensors, optically isolated (OI)

  • OXROB10-CL4-SUB: Stainless steel 10cm long, 3mm in diameter, 4m cable length (CL4), OI

  • OXROB3-SUB: Stainless steel 3cm long, 3mm in diameter, optically isolated (OI)

  • OXROB3-CL4-SUB: Stainless steel 3cm long, 3mm in diameter, 4m cable length (CL4), OI

  • OXF50-UHS-SUB: Fixed needle, 50-70µm sensor tip protrudes ca. 6mm, ultra-high speed (t90 < 0.3s)

  • OXF50-HS-SUB: Fixed needle, 50-70µm sharp sensor tip protrudes ca. 6mm, high speed (t90 < 0.8s)

  • OXF50-SUB: Fixed needle sensor tip, sensor tip protrudes ca. 6mm, 50-70µm sharp sensor tip

  • OXF1100-UHS-SUB: Fixed needle, Sensor tip protrudes ca. 2mm, ultra-high speed (t90 < 0.3s)

  • OXF1100-HS-SUB: Fixed needle sensor tip, sensor tip protrudes ca. 2mm, high speed (t90 < 0.8s)

  • OXF1100-SUB: Fixed needle sensor tip, sensor tip protrudes ca. 2mm

  • OXB430-UHS-SUB: Optical fiber 430µm in diameter, ultra-high speed response time (t90 < 0.3s)

  • OXB430-HS-SUB: Optical fiber 430µm in diameter, high speed response time (t90 < 0.8s)

  • OXB430-SUB: Optical fiber 430µm in diameter

  • OXB50-UHS-SUB: 50-70µm sharp sensor tip, ultra-high speed response time (t90 < 0.3s)

  • OXB50-HS-SUB: 50-70µm sharp sensor tip, high speed response time (t90 < 0.8s)

  • OXB50-SUB: 50-70µm sharp sensor tip

pH Sensors and Caps (minimal cross-sensitivity to high ionic strength)

  • PHCAP-PK8T-SUB: Total Scale pH measurement, robust optical pH sensor cap

  • PHCAP-PK8-SUB: Robust optical pH sensor cap, measurement range pH 7.0-9.0

  • PHCAP-PK7-SUB: Robust optical pH sensor cap, measurement range pH 6.0-8.0

  • PHROBSC-PK8T-SUB: Robust pH Probe, 6.0-8.0 range pH total scale,  exchangeable screw caps

  • PHROBSC-PK8-SUB: For pH measurements between pH 6.0-8.0,  exchangeable screw caps

  • PHROBSC-PK7-SUB: For pH measurements between pH 7.0-9.0, exchangeable screw caps

Shallow Water Oxygen OEM Meter with Oxygen Sensor Caps
Operation to depths of 50m
  • APHOX-S-O2 with APHOX-S-OXCAP

    • Factory calibrated ​

    • Corrosion and biofouling resistant housing

    • For temperature-compensated oxygen measurements

    • Analog outputs/RS485/Modbus

    • Operation down to 50 m depths

    • Exchangeable oxygen sensor caps

APHOX-S-ScrewCap Assembly v1.png

APHOX-S-O2

bottom of page