Biogas Analysis Services
Ohio Lumex is a leading source for comprehensive Biogas Analysis Services, including lab analysis and on-site sampling of waste-to-energy, landfill gas, wastewater, and other renewable energy projects. Our NELAP Accredited Laboratory offers an all-inclusive range of biogas analysis services performed according to industry methods and standards, including ASTM, ISO, EPA, etc.
​
We provide accurate results that are easy to understand, so you can make the right decisions about your system. Our highly trained and experienced staff will work with you to determine what type of analysis or services you need.
​
Our services apply to a variety of applications at biogas sites working with renewable energy, including RNG interconnection compliance (both startup and ongoing), pipeline integrity, process control, and various research and development efforts.
​
Let our trained technicians handle all aspects of your biogas project from start to finish, so you can focus on what’s really important.
Biogas Testing Services:
Test Methods:
-
ASTM D1945, D1946, D3588​
-
Hydrocarbon Dewpoint
Sampling Options:​
-
Passivated HP Cylinder*
-
Tedlar Bag
Total Hg
Test Methods:
-
EPA SW-846 Method 8270D (NDPA)​
​
Sampling Option:
-
SVOC Sorbent Trap
Downloads:
Test Methods:
-
EPA Method TO - 15
-
EPA SW-846 Method 8270D
(NDPA)
Sampling Option:​
-
SUMMA Canister
Major Gases and BTU:CO2, CH4, O2, N2, CO, H2, BTU, Wobbe Index
and Hydrocarbons (C2+)
Total and Speciated Sulfur
Test Methods:
-
ASTM D6228, D5504
Sampling Options:​
-
Passivated HP Cylinder*
-
Tedlar Bag
Ammonia in Biogas
Volatile Organic
Compounds (VOC)
Semi-Volatile Organic Compounds (SVOC-NDPA)
-
Weekly Sampling System Rentals
-
Weekly Sample Cylinder Rentals
-
Sorbent Tubes/Traps and Tedlar Bags for Purchase
-
Sampling system, instructions, and supplies to ensure your sampling team delivers quality samples for analysis
-
Online monitoring and batch samples using proprietary instrumentation and methodology
-
Training of Personnel
-
Commissioning and Installation
Biogas Onsite Services:
Biogas Sampling Equipment and Supplies:
Related Products:
* Recommended for Sample Stability and Sensitivity
Test Method:
-
ASTM D8230
​
Sampling Options:
-
Passivated HP Cylinder
-
SUMMA Canister
-
Tedlar Bag
Siloxanes and Silanols:
L2, L3, L4, L5,
D3, D4, D5, D6, TMSOL
Radiology
(Radon, Alpha and Beta)
Aldehydes and Keytones (including Formaldehyde)
Test Methods:
-
TO - 11A
Sampling Option:​
-
Sorbent Trap
Test Methods:
-
EPA 900/SW6020
-
E115
Sampling Option:​
-
Filter
-
Sorbent Trap
Test Methods:
-
ASTM D5454, D1142
Sampling Option:​
-
Portable Hydrometer
-
Portable Chilled Mirror
Moisture
Test Methods:​
-
EPA SW8081
Sampling Option:​
-
Impinger Sampling Train
Pesticides
Others available upon request
Test Methods:
-
qPCR Technique
​
Sampling Option:
-
Sterile MIC gas sampling device
Biologicals (MICs):
Total Bacteria, SRB,
APB, IOB
Test Method:
-
EPA SW8082
Sampling Option:​
-
Impinger Sampling Train
PCBs
Others available upon request
Test Method:
-
Modified EPA Method 29
​
Sampling Option:
-
Impinger Sampling Train
Metals in Gas:
As, Cu, Sb, Pb
Test Methods:
-
Modified EPA OTM-40
-
HCl/HF​
-
-
TO - 14 (Organic)
Sampling Options:
-
Passivated HP Cylinder
-
Tedlar Bag