Optical Oxygen Sensors
PyroScience optical oxygen sensors utilize patented REDFLASH technology that guarantees fast and accurate oxygen measurements with no sample consumption.
These optical sensors work well in a variety of different gaseous, aqueous, and semi-solid samples in many types of applications, including challenging environments like organic solvents, microfluidics, and high-throughput screenings. Absence of stirring sensitivity, long shelf life, and resistance to corrosive environments, like seawater, are among the many advantages of these optical sensors in comparison to the alternative technologies, e.g. electro-chemical sensors. Choose from a variety of fiber-optic and contactless oxygen sensors, as well as solvent-resistant oxygen probes.
PyroScience recommends using their OXCAL zero oxygen calibration capsules which can be purchased directly from us. Note that all contactless sensors require fiber optic cables and other accessories (depending on sensor type) for complete sensor systems.
If you are not sure which sensor type would fit your application best, consider getting one of our starter kits that include a few different sensor types. Alternatively, we are happy to discuss your application in more detail to help you find the best possible system and sensor solution.
Choose from a variety of robust, mini and micro sensors as well as unique solvent-resistant probes
Options include contactless sensors and nanoprobes. Customize your setup with oxygen sensor foil
An economical way to test out a few different sensors when you are unsure which one to pick
Fiber-Optic Oxygen Probes and Mini-/Microsensors
Contactless Optical Oxygen Sensors
Optical Oxygen Starter Kits
These probes work in gaseous and liquid samples and are compatible with all FireSting optical meter series*.
Choose from a variety of robust, mini- and microsensors and solvent-resistant probes.
-
OPDIP20: Standard range, dipping probe, 20cm long
-
OPROB3: Standard range, 3cm long, 1m cable
*Only compatible with PICO optical meter series
Robust Optical Oxygen Probe Options - PICO Series Only*
3mm tip diameter, response time (t90 < 7-15s), optically isolated
-
OXROB10: Standard range, 10cm long, 2m cable
-
OXROB10-HS: Standard range, high speed (t90 <0.5-3s), 10cm long, 2m cable - NEW
-
OXROB10-CL4: Standard range, 10cm long, 4m cable
-
TROXROB10: Trace range, 10cm long, 2m cable
-
OXROBSC: Screw cap, standard range, 10m long, 2m cable
-
OXROB3: Standard range, 3cm long, 2m cable
-
OXROB3-CL4: Standard range, 3cm long, 4m cable
-
TROXROB3: Trace range, 3cm long, 2m cable
Robust Optical Oxygen Probe Options
3mm tip diameter, response time (t90 < 7-15s), optically isolated
-
OXF1100: Standard range, response time (t90 < 3-5s), 2m cable
-
OXF1100-CL4: Standard range, response time (t90 < 3-5s), 4m cable
-
TROXF1100: Trace range, response time (t90 < 3-5s), 2m cable
-
TROXF1100-CL4: Trace range, response time (t90 < 3-5s), 4m cable
-
OXF1100-HS: Standard range, response time (t90 < 0.8s), 2m cable
-
OXF1100-UHS: Standard range, response time (t90 < 0.3s), 2m cable
-
OXF1100-OI: Optically isolated, standard range, response time (t90<6-10s), 2m cable
-
OXF1100-OI-CL4: Optically isolated, standard range, response time (t90<6-10s), 4m cable
Fixed Fiber Optical Oxygen Minisensor Options
430µm tip diameter, tip protrudes ca. 2mm, 40mm needle length
Retractable Fiber Optical Oxygen Minisensor Options
430µm tip diameter, 4-step sliding mechanism, 40mm needle length
-
OXR430: Standard range, response time (t90 < 3-5s), 2m cable
-
OXR430-CL4: Standard range, response time (t90 < 3-5s), 4m cable
-
TROXR430: Trace range, response time (t90 < 3-5s), 2m cable
-
OXR430-HS: Standard range, response time (t90 < 0.8s), 2m cable
-
OXR430-HS-CL4: Standard range, response time (t90 < 0.8s), 4m cable
-
OXR430-UHS: Standard range, response time (t90 < 0.3s), 2m cable
-
OXR430-OI: Optically isolated, standard range, response time (t90 < 6-10s), 2m cable
-
OXR430-OI-CL4: Optically isolated, standard range, response time (t90 < 6-10s), 4m cable
Bare Fiber Optical Oxygen Minisensor Options
430µm tip diameter, for special geometries
-
OXB430: Standard range, response time (t90 < 3-5s), 2m cable
-
TROXB430: Trace range, response time (t90 < 3-5s), 2m cable
-
OXB430-HS: Standard range, response time (t90 < 0.8s), 2m cable
-
OXB430-UHS: Standard range, response time (t90 < 0.3s), 2m cable
-
OXB430-UHS-CL4: Standard range, response time (t90 < 0.3s), 4m cable
-
OXB430-OI: Optically isolated, standard range, response time (t90 < 6-10s), 2m cable
-
OXF500PT: 500µm needle diameter, response time (t90 < 3-5s), 2m cable
-
OXF500PT-OI: Optically isolated, 500µm needle diameter, response time (t90 < 6-10s), 2m cable
-
OXF500PT-OI-CL4: Optically isolated, 500µm needle diameter, response time (t90 < 6-10s), 4m cable
-
OXF900PT: 900µm needle diameter, response time (t90 < 3-5s), 2m cable
-
OXF900PT-OI: Optically isolated, 900µm needle diameter, response time (t90 < 6-10s), 2m cable
Protected Tip Fiber Optical Oxygen Minisensor Options
Standard range, 40mm needle length, optimized for gas measurements, sensor tip glued into needle
Bare Fiber Optical Oxygen Microsensor Options
Standard range, 50-70µm tip diameter, for special geometries
-
OXB50: Response time (t90 < 3-5s), 2m cable
-
OXB50-CL4: Response time (t90 < 3-5s), 4m cable
-
OXB50-HS: Response time (t90 < 0.8s), 2m cable
-
OXB50-UHS: Response time (t90 < 0.3s), 2m cable
-
OXB50-OI: Optically isolated, response time (t90 < 6-10s), 2m cable
-
OXB50-OI-CL4: Optically isolated, response time (t90 < 6-10s), 4m cable
Fixed Fiber Optical Oxygen Microsensor Options
50-70µm tip diameter, sensor tip protrudes ca. 6mm, 40mm needle length
-
OXF50: Standard range, response time (t90 < 3-5s), 2m cable
-
OXF50-HS: Standard range, response time (t90 < 0.8s), 2m cable
-
OXF50-UHS: Standard range, response time (t90 < 0.3s), 2m cable
-
OXF50-OI: Optically isolated, response time (t90 < 6-10s), 2m cable
Retractable Fiber Optical Oxygen Microsensor Options
Standard range, 50-70µm tip diameter, 4-step sliding mechanism, 40mm needle length
Specifications
Dimensions
-
OXR50: Response time (t90 < 3-5s), 2m cable
-
OXR50-CL4: Response time (t90 < 3-5s), 4m cable
-
OXR50-HS: Response time (t90 < 0.8s), 2m cable
-
OXR50-UHS: Response time (t90 < 0.3s), 2m cable
-
OXR50-UHS-CL4: Response time (t90 < 0.3s), 4m cable
-
OXR50-OI: Optically isolated, response time (t90 < 6-10s), 2m cable
-
OXR50-OI-CL4: Optically isolated, response time (t90 < 6-10s), 4m cable
Solvent Resistant Optical Oxygen Sensor Options
Response time (t90 < 9s), 1.5 mm needle diameter, for oxygen monitoring in organic solvents
-
OXSOLV: Sensor tip protrudes ca. 2 mm, needle length 150 mm, 1m cable
-
OXSOLV-PTS: Protected sensor tip, fiber glued into the needle, needle length 40 mm, 1m cable
Optical Oxygen Sensor Spot Options
Requires transparent surface, fiber optic cables and adapters for complete setup
-
OXSP5: Regular range, autoclavable, response time (t90 < 7-16s), requires SPGLUE silicon glue
-
TROXSP5: Trace range, autoclavable, response time (t90 < 7-16s), requires SPGLUE silicon glue
-
OXSP5-ADH: Regular range, autoclavable, response time (t90 < 7-16s), self-adhesive
-
TROXSP5-ADH: Trace range, autoclavable, response time (t90 < 7-16s), self-adhesive
-
OXSP5-SUB: Regular range, autoclavable, response time (t90 < 5s), requires SPGLUE silicon glue
-
OXSP5-ADH-STER: Regular range, beta-sterilized, response time (t90 < 7-16s), self-adhesive,
-
TROXSP5-ADH-STER: Trace range, self-adhesive, beta-sterilized, response time (t90 < 7-16s)
Optical Oxygen Flow-Through Cell Options
For inline oxygen and temperature monitoring with specified flow rates, varied response times
-
TOFTC2: Integrated O2 and temp sensor, for ca. 3.2 or 4.0mm ID tubings, flow rate: 20-500mL/min
-
OXFTC: Integrated O2 sensor, for ca. 1.6 or 2.4mm ID tubings, flow rate: 10-100mL/min
-
OXFTC2: Integrated O2 sensor, for ca. 3.2 or 4.0mm ID tubings, flow rate: 20-500mL/min
These cells are Now Sterilized:
-
OXFLOW: cell with integrated O2 sensor, sterilized using 25kGy beta-irradiation
-
OXFLOW-HS: cell with integrated O2 sensor, sterilized using 25kGy beta-irradiation, high speed
-
TROXFLOW: cell with integrated O2 sensor, sterilized using 25kGy beta-irradiation, trace range
These sensors work in gaseous and liquid samples and are compatible with all FireSting and PICO optical meter series. Options include oxygen sensor spots, flow-through cells, respiration vials and oxygen nanoprobes.
Optical Oxygen Sensor Vial Options
For measurements in closed containers, requires fiber cables and adapters for complete setup
-
OXVIAL4: 4ml vial with integrated oxygen sensor strip
-
OXVIAL20: 20ml vial with integrated oxygen sensor strip
-
TOVIAL20: 20 ml vial with integrated oxygen and temperature sensor strips
-
PHTOVIAL20-PK7: 20 ml vial with integrated oxygen, pH range 6.0-8.0 and temperature sensor strips
-
PHTOVIAL20-PK8: 20 ml vial with integrated oxygen, pH range 7.0-9.0 and temperature sensor strips
Oxygen Nanoprobes
Ideal for microfluidics and lab-on-a-chip applications
-
Dispersible oxygen nanoprobes
-
Requires transparent windows for read-out
-
Autoclavable
-
Real-time response
-
Diameter of a single nanoprobe bead is 200 - 300nm
-
Requires an optical cable or rod for compete setup
An economical way to test out a few different sensors when you are unsure which one to pick.
Optical Oxygen Starter Kits
Limit one (1) kit per meter purchase
-
OXKIT-CTL: Includes 1/2 OXFTC, OXSP5, SPFIB-BARE, 1/4 SPADBAS, 1/4 OXVIAL4, ADVIAL4
-
OXKIT-CTL-PIC: Includes 1/2 OXFTC, OXSP5, PICFIB2, ¼ SPADBAS, 1/4 OXVIAL4, ADVIAL4
-
OXKIT-FOP: Includes OXR50, OXF1100, OXROB10
-
OXKIT-FOP-OI: Includes OXR50-OI, OXF1100-OI, OXROB10
Oxygen Calibration Capsules
10 capsules per pack, each capsule results in 50mL buffer solution
-
OXCAL: Calibrations capsules for 50ml 0% O2 solution, for 0% calibration of optical O2 sensors
Oxygen Calibration Capsules
Necessary Accessories for Sensor Spots, Vials and Flow-through Cells
Compatible with Oxygen, pH and Temperature Contactless Sensors
-
SPFIB-BARE: optical fiber, for contactless readout, to measure through 0-2mm thickness, 1m length
-
SPFIB-LNS: optical fiber with lens, to measure through 3-10mm thick materials, 1m length
-
SPADBAS: Basic spot adapter, compatible to SPFIB-BARE, PICFIB2 or PICROD2, SPGLUE for fixation
-
SPFIB-BARE-CL2: same as SPFIB-BARE, 2m length
-
SPFIB-LNS-CL2: same as SPFIB-LNS, 2m length
-
SPFIB: optical fiber, for contactless readout, to measure through 0-2mm thickness, 1m length, ST-connector on both ends
-
SPGLUE: Transparent silicone glue Elastosil E43, (ca. 90 ml), for fixing sensor spots or SPADBAS
-
SPGLUE-KIT: Glueing kit with 1 spoon spatula (SPTLA), disposable syringe with screw cap, Luer-Lock fixture, 5 flat needles
-
SPTLA: 300mm long spatula for handling sensor spots, to position and fix sensor spot during gluing
-
ADVIAL20T: Adapter ring for 20mL vials with up to 3 sensors, compatible to SPFIB-BARE and PICFIB2
-
ADVIAL4T: Adapter ring for 4mL vials with up to 2 sensors, compatible to SPFIB-BARE and PICFIB2
-
SEPVIAL4: Septa with lids (with and without hole), for replacement in 4mL sensor vials
-
SEPVIAL20: Septa with lids (with and without hole), for replacement in 20mL sensor vials
-
ADPATCH: adhesive sticker patches, for piercing with protected O2 minisensors
-
PICFIB2: fiber for contactless readout with PICO-type meters only, for 0-10mm thick walls, 1m length
-
PICROD2: optical fiber rod, with PICO-connector, for 0-10mm thick walls, ca. 40mm length
-
PICROD3: optical fiber rod, PICO-connector, Ø = 3mm, 51.5mm length, for 0-20mm thick walls
-
PICFIB2-LNS: same as PICFIB2 but for 0-20mm thick walls
-
PICROD2-LNS: same as PICROD2 but with focusing lens, ideal for microfluidics
-
SPFIB-LNS-SUB: same as SPFIB-LNS, but with underwater SUB-connector (SUB)
-